PRODUCTS
> PRODUCTS > Speaker Fo/Ze Tester > SG-2882A
SG-2882A Watch Video
    SG-2882A

  • Introduction:
    This device utilizes constant voltage measurement method and constant current measurement method to automatically measure the minimum resonant frequency (Fo), nominal impedance (Ze), and Qo. A new algorithm is applied in order to find the resonant frequency for sweeping a large bandwidth with quick and precise measurement. The result of the measurement can be collected from the PC, and the program can control the measuring instrument in real time. In the PC control program, the T/S option can be added to measure Thiels-Small parameter.


  • Special Feature:
    1. Quick automatic measurement is available due to the new algorithm for the measurement of the speaker’s Fo.
    2. You can select the measurement methods, constant voltage measurement method and constant current measurement method.
    3. You can set the passing ranges of Fo and Ze for pass/fail management.
    4. The statistics processing function calculates and gives the maximum value, minimum value, mean value, and the standard   deviation of the measured values.
    5. The set data of at most 100 models can be saved to be selected.
    6. Either linear or log values of the sweep method can be set for precise or wide range of bandwidth measurement, according to   the conditions.
    7. In case of constant voltage measurement (1V standard), the speaker impedance can be measured between 1Ω~20KΩ,   making the measurement of low impedance speaker to high impedance piezoelectric speaker.
    8. The measured data can be stored up to 2,000 units, and it is collected by the control program, to be saved or printed.
    9. The PC control program has configuration and measurement functions, and when option 2 is used, Thiel-Small parameter
       can be measured.


  • Constitute:
    1. A/D Converter : 24bit 2channer.
    2. DISPLAY : 480 X 272 4.2” TFT-LCD
    3. Interface Bus : USB 2.0
    4. Remote control interfaces : 9P D-Type Connector. I/O Signal-Start, Pass, Fail
    5. Main Power requirements : AC 220V 50/60Hz 50VA / OPTION : 110V
    6. DIMENSION : 250 (W) * 150 (H) * 320 (D) mm
    7. weight : 4kg


  • Specification:
      Fo Ze
    OUTPUT VOLT 0.1 - 5V (Rms) ± 1% + 1Dig 0.1 - 5V (Rms) ± 1% + 1Dig
    OUTPUT CURRENT
    20 ~ 1000mA
    2mA ~ 100mA
    0.2mA ~ 10mA
    ( ± 1% + 1Dig)

    20 ~ 1000mA
    2mA ~ 100mA
    0.2mA ~ 10mA
    (± 1% + 1Dig)
    MEASUREMENTS
    IMPEDANCE
    1 ~ 100
    50 ~ 1K
    500 ~ 10K
    (± 1% + 1Dig)
    1 ~ 100
    50 ~ 1K
    500 ~ 10K
    (± 1% + 1Dig)
    MEASUREMENT
    ACCURACY
    Narrow
    1/12 Oct
    1/24
    1/48
    1/96
    1/192
    1/384
    Linear
    (± 1% + 1Dig)
    ± 1% + 1Dig (>0.1mA)





    * CONSTANT CURRENT
    20 ~ 80mA = 1 ~ 100
    2 ~ 8mA = 50 ~ 1K
    0.2 ~ 0.4mA = 500 ~ 10K
    Broad 1/ 96 Oct ± 5% + 1Dig
    1/192 Oct ± 2% + 1Dig
    1/384 Oct ± 1% + 1Dig
    Linear ± 1% + 1Dig
    FREQUENCY ACCURACY 10Hz ~ 20KHz ± 0.2%
    100Hz ~ 20KHz ± 0.03%
    10Hz ~ 20KHz ± 0.2%
    100Hz ~ 20KHz ± 0.03%
    BAND WIDTH
    THD
    10.0 Hz - 20.00 KHz
    * THD (1V Rms) < 0.2%
    10.0 Hz - 20.00 KHz
    * THD (1V Rms) < 0.2%
    MAX OUTPUT VOLT 10V (Rms) 10V (Rms)
    MAX OUTPUT CURRENT 1000 mA 1000 mA
    STATISTIC QUANTITY 2000 EA 2000 EA
    PASS IN WIDTH FREQUENCY WIDTH OF SELECT RANGE
    Impedance WIDTH OF SELECT RANGE
    MEASUREMENTS
    SPEED
      Narrow – 4Sec (Average) 1 Sec
    Broad
    Sweep
    (Max Time)
    10Hz~20KHz
    SWEEP [1]

    1/12
    [2]

    1/24
    [3]

    1/48
    [4]

    1/96
    6sec 12sec 23sec 46sec
    [5]

    1/192
    [6]

    1/384
    [7]

    Linear
     
    92sec 184sec 237sec  


  • Option 01 - Data Acquisition software

    The Acquisition Software allows the user to upload and download stored data in the SG-2882 to and from a computer and take control of its operation. It also enables the computer to save, analyze, and print the data.

      - All functions of SG-2882 can be controlled with the PC.
      - up to 100 measurement conditions can be set for up/down load using SG-2282.
      - The measurement results can be saved as html or text, or be printed.


  • Option 02 - Thiels Small Parameters

    Selection of Option 001 + Option002 enables SG-2882 to compute T/S parameters on a computer connected to it as well as an ‘Add Mass’ value in the event a speaker’s mass has changed and an ‘Add Volume’ value in the event a test box’s area has changed.

      - The T/S parameter can be obtained from the value measured through SG-2882
      - Measurement category: Fs, F1, F2, Zmax, Zts, r∮, Symmetry, Qms, Qes, Qtc, EBP, BL, Vas, Mms, Cms, Rms, Mas, Cas, Ras, no, Fs’, F1’, F2’, Zmax’, Zts’, Sysm’. [ Add Mass, Add Volume]
    [Symbol definitions and units]
    ro = Max. Voice-coil impedance to DC-resistance ratio
    Symmetry = Symmetry of resonance peak
    Qms = Mechanical Q in free air
    Qes = Electrical Q in free air
    Qts = Total Q in free air
    LVC(1KHz) = Voice coil inductance at 1KHz
    EBP = Efficient bandwidth product
    BL = driver transduction constant in Tesla-meters
    Vas = Compliance equivalent air volume
    Mms = Mechanical mass of diaphragm assembly, including air
    Cms = Mechanical Compliance of driver suspension
    Rms = Mechanical resistance of driver suspension losses
    Mas = Acoustical mass of diaphragm assembly, including air
    Cas = Acoustical compliance of driver suspension
    Ras = Acoustioal resistance of driver suspension losses
    no = Acoustical reference efficiency
    Fs = Resonance frequency
    Zmax = Impedance at resonance frequency
    Zts = Sometimes Called the Thiels Small impedance



Sigma Electronics Technology  |  Address : 115, 58 Street, Seo-jeon Lo, Jeonpodong, Jin-gu, Busan, Korea  |  TEL : +82-51-805-1718   |   FAX : +82-51-805-4520