PRODUCTS
> PRODUCTS > Audio/Sound Analyzer >SG-5622A
SG-5622A
    SG-5622

  • Introduction
    This signal analyzing equipment enables us to conduct a simultaneous measurement for frequency response generated from loud speaker, SPL, impedance, Fo, Ze, THD, Phase, polarity, and Rub & Buzz. High-frequency signal analysis offers even more accurate testing and identification of Rub&Buzz than existing hearing tests. The algorithm of signal analysis applied to this device allows to detect even minute Rub & Buzz due to its innovative and new method. The 4-stage defect setting enables even more in-depth assessment.

  • Features
    • Linear and Log(Octave) System analysis.
    • Impedance – Voltage and current measurement for loudspeakers.
    • High performance SNR>100dB
    • 24Bit Sampling frequency up to 48kHz.
    • Computer-controlled operation Fast, hot plug USB interface.
    • Easy reporting using Microsoft® Word or Excel (Text Format)
    • Calibration of input and output signals in commonly used units
    • Simple Constitution: Audio Analyzer has built-in Audio Amplifier and Conditioning Amplifier.

    • A simultaneous measurement of Frequency Response, SPL, Harmonics Impedance, Fo, Ze, THD, Phase, Polarity, and Rub&Buzz provides fast results
    • The control line is divided into four classes for grading control.
    • Can perform Self Test to check condition of hardware system.
    • Measurement data is recorded as a file and the Avg, Min, Max, Cp, and Cpk of SPL, Fo, Ze, THD(4point), and Rub&Buzz(4point) can be calculated (SPC).
    • Can perform remote control through the Internet.
    • Can connect to an automation system by installing Option-01A.
    • If the results show “Fail” due to an external noise (shock, etc) during the measurement, measurement is run automatically again.
    • Stereo product can be effectively inspected since CH-A and CH-B are measured at the same time.

  • SG-5622A Technical Specifications

    Generator & Analyzer
    Level flatness of the combined generator & analyzer
    100 Hz ~ 10kHz
    20 Hz ~ 20 kHz


    Sweep Generator
    Number of channels
    Sampling rate (fs) / Level resolution
    Frequency range

    Level setting resolution
    Amplitude shape dynamic range
    Level accuracy @ 1 kHz
    Level flatness
    100 Hz ~ 10 kHz
    20 Hz ~ 20 kHz
    Frequency resolution

    Frequency accuracy
    Power Amplifier Output Voltage range
    Total Harmonic Distortion




    Sweep Analyzer
    Number of channels
    Sampling rate (fs) / Level resolution
    Bandwidth
    Level range
    Level accuracy @ 1 kHz
    Level flatness
    100 Hz ~ 10 kHz
    20 Hz ~ 20 kHz

    Residual distortion @ level +20 to –20 dBVp (THD+N)
    Residual noise
    Phase accuracy (interchannel)

    Internal frequency accuracy
    Selectable input impedance per channel
    Input impedance accuracy
    Input impedance coupling
    Phantom power voltage
    Phantom voltage accuracy
    Phantom power inward resistance
    15V

    Measurements








    Option & Accessories

    Phanton power voltage

    Polarization Voltage

    SP-72

    SG-5001B






    General

    Standard software




    Interface Bus


    Main power requirements

    Fuse

    Operating temperature

    Dimensions

    Weight




    <± 0.1 dB
    <± 0.2 dB



    2 channels with individual levels
    48 kHz / 24 bit DAC
    20 Hz ~ 20 kHz

    0.1 dB
    94 dB
    <± 0.1 dB

    <± 0.1 dB
    <± 0.2 dB
    Log : 1/1,1/3,1/6,1/12,1/24,1/48 Octave steps
    Lin : 1 to 2000 steps
    <± 50 ppm
    10mVRMS to 10.0VRMS , 5W [Max]
    0.1V (8Ω) at 1 kHz -60 dB
    1V to 5V (8Ω) at 1 kHz -65 Db



    2 independent channels with individual input range
    48 kHz / 24 bit
    20 Hz ~ 20 kHz
    -34 to + 60 dBVp
    <± 0.1 dB

    <± 0.1 dB
    <± 0.2 dB

    <-85 dB
    <-120 dB
    ± 1 deg @ 200 Hz ~ 4 kHz

    ± 50 ppm
    1 MΩ
    1% of resistor value
    AC Coupled
    15 VDC
    ± 0.5 VDC

    2.2 KΩ

    [1] SPL (Sound Pressure Level) Frequency Response
    [2] Total Harmonic Distortion / 2nd & 3rd Harmonisc Distortion
    [3] Extraneous Noise (Rub&Buzz) Frequency Response
    [4] Impedance Frequency Response
    [5] Polarity (Phase Frequency Response)
    [6] Impedance
    [7] Fo, Ze (Resonance Frequency)
    [8] L/R Comparison measurement



    Connector type BNC 24 VDC, 48 VDC

    Connector type 7 pin Lemo 200 VDC

    Lemo ICP Adaptor

    Remote Control
    15P D-Type connector I/O signal - Start, Pass, Fail, Fail [Class1, Class2, Class3, Class4]
    SPL Analyzer ON. Rub & Buzz Analyzer ON .
    Remote control I/O ※ Terminal Box [Option 01A]




    Audio Analyzer Production software
    (PC based Windows® XP, Vista, win7 )
    Pentium®4, 1.5GHz processor minimum or equivalent.
    (Celeron processors are not recommended)

    Personal computer connected to the instrument
    through the Audio Analyzer Interface Bus. (USB2.0)

    AC 220-230V~ 50/60Hz 95VA

    5 x 20 T LBC 1A/250V Standard : EN10480

    + 5 to +45℃ ( +40 to +110 F ), R.H.<90% non condensing

    485(W) * 95(H) * 256(D) mm (without Dimensions of Power Amp)

    4.2 kg (without Weight of Power Amp)



Sigma Electronics Technology  |  Address : 115, 58 Street, Seo-jeon Lo, Jeonpodong, Jin-gu, Busan, Korea  |  TEL : +82-51-805-1718   |   FAX : +82-51-805-4520
관리자접속